Direct answer

This is the Maine certified-lab path for private-well owners. Start with Maine CDC’s in-state commercial PDF or the All Accredited Laboratories spreadsheet. Maine CDC’s published cadence is coliform, E. coli, nitrate, and nitrite every year, and arsenic (plus other metals and radon) every 3–5 years. Bacteria or nitrate still goes to the health department.

What to test
What to testWhyEPA MCL / SMCL or guidance
Total coliformCDC’s annual floor for a private well. A present result is a pathway warning, not a shopping trip.Present/absent — any detected coliform is a positive until a clean retest CDC well-testing guidelines
Nitrate as NSame yearly panel as coliform. A result at or above the public-system line goes to the health department.10 mg/L as N (EPA public-system MCL) EPA National Primary Drinking Water Regulations
ArsenicInvisible in the glass. Compare a certified-lab µg/L to the public-system MCL.0.010 mg/L / 10 µg/L (EPA public-system MCL) EPA Arsenic Rule
UraniumInvisible in the glass. Maine CDC’s MEG and EPA’s public-system MCL use the same concentration.30 µg/L EPA public-system MCL / Maine MEG (not a private-well statute) EPA Radionuclides Rule

A working inventory of laboratories on Maine CDC’s in-state commercial drinking-water list. Confirm current drinking-water accreditation in the official files before you mail a sample.

Maine CDC accredits environmental laboratories for the tests they offer. The public listings are the in-state commercial PDF (updated 5/16/2026) and the All Accredited Laboratories spreadsheet. Accreditation is by analyte. This page is a directory, not a substitute for those live files. Maine CDC tells private-well owners to test every year for coliform, E. coli, nitrate, and nitrite, and every 3–5 years for arsenic, chloride, copper, fluoride, hardness, iron, lead, magnesium, manganese, pH, radon, sodium, and uranium. Arsenic, radon, and uranium show up in Maine wells; they are extras to ask the lab about, not a diagnosis on this page. Maine’s 20 ng/L public-system PFAS sum is not a private-well MCL — use the PFAS in private well water guide for EPA’s comparison table, and the certified-labs-by-state hub for the official-search path. For the arsenic MEG, the USGS one-in-ten figure, and who to call after a sheet, use the Arsenic in Maine well water guide — not a filter brand. For the uranium MEG of 30 µg/L, the tip-sheet cooking split, and Yang et al. sample-size caveats, use the Uranium in Maine well water guide. If coliform or nitrate fails, take the sheet to the health department.

News for ME well ownersCertified labs by stateArsenic in Maine well waterUranium in Maine well waterPFAS in private well waterFlorida certified labsIowa certified labsPennsylvania certified labsNew York certified labsNew Hampshire certified labs

Official search first

Open Maine CDC Laboratory Accreditation. Use In-State Maine Accredited Commercial Laboratories (PDF) for labs that publish a Maine phone, and All Accredited Laboratories (Excel) for the full method-and-analyte list. Labs are accredited by the tests they offer. Confirm coliform, nitrate, and any metal or radionuclide you need. Then call about bottles, hold times, and whether a mailed bacteria sample can arrive inside the hold time. The Drinking Water Program accreditation officer is 207-287-2070.

Maine CDC Laboratory Accreditation

Labs that take private-well work

Listing here is not a certification. Phone the lab, ask for current drinking-water fields of accreditation, hold times, and whether they want a Friday bacteria sample. If the result is coliform or nitrate, take the sheet to your health department.

  • Augusta · Kennebec / statewide kits

    Private wells: yes

    Health and Environmental Testing Laboratory (HETL)

    Augusta, ME

    207-287-2727

    Maine CDC’s public-health lab. The 5/16/2026 commercial list publishes this Augusta number. The All Accredited Laboratories spreadsheet lists Safe Drinking Water Program fields that include total coliforms, E. coli, nitrate as N, nitrite as N, arsenic, lead, and uranium (lab ID ME01073). The Environmental Chemistry page also describes radiochemistry and radon testing; confirm the current drinking-water fields before you order radon.

    Maine CDC tells private-well owners to test every year for coliform, E. coli, nitrate, and nitrite, and every 3–5 years for arsenic, chloride, copper, fluoride, hardness, iron, lead, magnesium, manganese, pH, radon, sodium, and uranium. If coliform or nitrate fails, take the sheet to the health department — this site is not medical advice.

    Lab website · Maine CDC in-state commercial labs PDF and HETL Environmental Chemistry

  • Auburn · Androscoggin / central Maine

    Private wells: call to confirm

    Eurofins Auburn (previously A&L)

    Auburn, ME

    207-784-5354

    In-state commercial lab on the 5/16/2026 PDF (lab code LAB-EWA). The All Accredited Laboratories spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, nitrate as N, and nitrite as N (lab ID ME01076).

    Listing here is not a certificate. Confirm current drinking-water fields in the Excel file or with the accreditation officer at 207-287-2070 before you mail a bottle.

    Lab website · Maine CDC in-state commercial labs PDF

  • Portland · Cumberland / bacteria

    Private wells: call to confirm

    Eurofins Portland ME

    Portland, ME

    207-846-6569

    The 5/16/2026 PDF lists this lab as bacteria only (lab code LAB-EEP). The spreadsheet lists Safe Drinking Water Program fields for total coliforms and E. coli (lab ID ME01075).

    Do not assume nitrate, metals, or radon are in the same bottle. Chemical work needs a lab accredited for those analytes. Confirm hold times if you mail a bacteria sample.

    Lab website · Maine CDC in-state commercial labs PDF

  • Kennebunk · York / southern Maine

    Private wells: call to confirm

    Nelson Analytical Lab — Maine

    Kennebunk, ME

    207-467-3478

    In-state commercial lab on the 5/16/2026 PDF (lab code NLSON). The spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, nitrate as N, nitrite as N, arsenic, lead, and uranium (lab ID ME00015).

    A New Hampshire Nelson location also appears in the spreadsheet. Use the Kennebunk number from the Maine commercial PDF unless the lab tells you otherwise. Confirm current fields before you order.

    Lab website · Maine CDC in-state commercial labs PDF

  • Winslow · Kennebec / central Maine

    Private wells: call to confirm

    NELAnalytical (previously Northeast Laboratory Services)

    Winslow, ME

    207-873-7711

    In-state commercial lab on the 5/16/2026 PDF (lab code NELAB). The spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, nitrate as N, nitrite as N, arsenic, lead, and uranium (lab ID ME00009).

    Listing here is not a certificate. Ask whether they still take a homeowner bottle and which tests are on the current certificate.

    Lab website · Maine CDC in-state commercial labs PDF

  • Scarborough · Cumberland / southern Maine

    Private wells: call to confirm

    Katahdin Analytical Services (SGS Scarborough)

    Scarborough, ME

    207-874-2400

    In-state commercial lab on the 5/16/2026 PDF (lab code KTHDN). The spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, nitrate as N, nitrite as N, arsenic, iron, lead, and uranium (lab ID ME00019).

    The PDF notes many labs offer statewide service and that mailed bacteria samples must meet hold times. Call before you ship.

    Lab website · Maine CDC in-state commercial labs PDF

  • Wiscasset · Lincoln / midcoast

    Private wells: call to confirm

    Maine Coast Laboratory (DBA Water Quality & Compliance Services Inc.)

    Wiscasset, ME

    207-882-5476

    In-state commercial lab on the 5/16/2026 PDF (lab code MEC). The spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, and nitrate as N (lab ID ME01032).

    Confirm nitrite, metals, and radon separately. The PDF website prints as waterqualityservicesme.com.

    Lab website · Maine CDC in-state commercial labs PDF

  • Newport · Penobscot / central Maine

    Private wells: call to confirm

    ClearWater Laboratory (Acheron Engineering)

    Newport, ME

    207-368-5786

    In-state commercial lab on the 5/16/2026 PDF (lab code CLWR). The spreadsheet lists Safe Drinking Water Program fields for total coliforms, E. coli, nitrate as N, and nitrite as N (lab ID ME00030, Acheron Inc. dba ClearWater Laboratory).

    Confirm they accept a private-well bottle. Do not treat an engineering-firm website as a current certificate.

    Lab website · Maine CDC in-state commercial labs PDF

  • Presque Isle · Aroostook / bacteria

    Private wells: call to confirm

    Mi'Kmaq Environmental Laboratory

    Presque Isle, ME

    207-764-4001

    The 5/16/2026 PDF lists this lab as bacteria only (lab code MNL). The spreadsheet lists Safe Drinking Water Program fields for total coliforms and E. coli (lab ID ME01009).

    Nitrate, arsenic, and radon need a lab accredited for those fields. If bacteria is present, call the health department. This site is not medical advice.

    Lab website · Maine CDC in-state commercial labs PDF

Maine CDC offices that answer private-well questions

These numbers are published on Maine CDC pages. They are the health-department path, not a shopping-cart kit. The commercial PDF also tells you to call 207-287-2070 for the Laboratory Accreditation Officer when you need to know which tests a lab currently holds. Hours change; call before you drive.

OfficeCounties servedPhone
Maine CDC Environmental Health / Toxicology (private-well questions)Statewide: what to test for and what results mean207-287-4311 or 866-292-3474
Maine CDC Drinking Water Program (April Bledsoe)Statewide: wells, sampling, treatment class, disinfection207-215-7124
Maine CDC Laboratory Accreditation OfficerStatewide: confirm a lab’s current drinking-water fields207-287-2070
Maine CDC Laboratory Accreditation (Christine Blais)Statewide accreditation program contact207-287-3220

Contaminant and parent pages

Related

See also the homepage, certified labs by state, well water test kits, how to read a lab report, and ME lab news.

Test the wellMatch a filter